PRODUCTS | MAGNETIC
LIFTING EQUIPMENT
There are currently Five different
types of Permanent Magnet Hoisters avaiable
with different performance, sizes and weights.
MaxX 250
MaxX 500
MaxX 1000
MaxX 1500
MaxX 2000
In order for the hoister to function in an appropriate
and lasting way, the chosen model must be adequate
for the work needed.
The parameters that must be taken into consideration
are:
Lifting Power: it is to be determined
by the maximum weight to be lifted (lifter plus
load). It must never exceed that of the lifting
apparatus (crane, etc.).
Load
Features: the material must have a smooth
and clean surface, must be of adequate thickness
and must be ferromagnetic. The steel must be
of low carbon content otherwise, if "bonded",
appropriate reductions should be made
CONSTRUCTION
The
Maxx mechanical structure provides very few
components. Rotor and stator, made of steel
and with a high magnetic permeability degree,
are obtained through mechanical manufacturing
of a solid workpiece, controlled by digital
machines. This ensures the desired uniformity,
solidity and quality needed for mass-produced
magnetic lifters.The material used (steel, aluminum,
plastic) is easy to dispose of and to recycle
when dismantling the machine.
The magnetic material used with high specific
energy, has allowed the manufacturer to highly
reduce product weight and size. In order to
ensure high quality of performance, the Maxx
lifter is magnetized all in one go after assembly,
by means of the greatest magnetizing apparatus
ever made in Europe. The manufacturer carries
out all the required tests on the lifter before
it is delivered to the customer.
PERFORMANCE
The
nominal lifting power is based on a steel load
with a greater thickness than the width of the
polar expansion. For any material other than
soft steel the following reduction factors must
be used to calculate the appropriate lifting
power: alloy steel=0.8: steel with a high amount
of carbon= 0.7: cast iron=0.45. The thickness
of the load also influences the lifting power
of the hoister: for those thicknesses smaller
than the polar width there is a reduction, in
the lifting power, proportional to the ration
of the thickness and the following width: K
= S/l
The load temperature must not exceed 80°C;
for greater temperatures contact our technical
staff
A) Load characteristics: Hoisting performance
is shown on the nameplate on each individual
hoister together with the
geometric characteristics of the load. Said
performance is also shown in the following pages
and it is relative to the different hoister
models.

|